Home Consul Consolidated Pvt Ltd,UPS (Uninterrupted Power Supply System)

UPS (Uninterrupted Power Supply System)

Consul Consolidated Pvt Ltd,Consul Digital Range


Features:
Consul Consolidated Pvt Ltd, Consul Consolidated Pvt Ltd,
  Consul Digital Range
Consul Consolidated Pvt Ltd, Consul Consolidated Pvt Ltd, Consul Consolidated Pvt Ltd,
   

Input

Voltage 160V - 270V
Frequency 46 to 54 Hz
Power Factor 0.99 to unity

Output

Voltage 220/ 230V
Phase 1 - 2W + G
Voltage Regulation + 1%
Frequency 50 Hz + 0.1%
Power Factor 0.7
Waveform Distortion Pure sinewave < 3% at full load (non linear load), <2% (Linear load)
Crest Factor 3 : 1
Over load Capacity 125% for 25 seconds
Efficiency AC to AC > 90%

Battery

Charger Built in solid state float-cum-boost charger with automatic boost/ trickle charge modes with current limit futures
Transfer Time 0 Ms,on line

Bypass

  Synchronized static bypass

Indicators

User friendly MIMIC panel UPSs Status, Battery level, Load level, Fault
Multi function LED display Line, Inverter, Bypass, Fault, Battery/ Load level
LCD Display Input and Output voltage, Input and Output frequency, Load %, Battery% for 1,2 and 3 KVA.

Audible Alarm

AC Failure Sounds every 4 seconds after line fails
Battery Low Sounds every second when approaches battery low level
UPSs Fault Continuous alarm

Protection

Over/ Under Voltage at I/P Yes
Short circuit & overload The UPSs shuts down and will not transfer to the bypass mode when a short circuit occurs on the output of the unit. After the short circuit being removed the UPSs will operate normally again. At short condition, the Fault LED lights as a warning to end users. Protection through MCBs and advanced electronic circuitry.
Lightning Protection Yes
Surge Protection Yes
Environment O °C to 40°C , 0-90% Rit Non Condensing
Interface Port DB - 9 connector or RS232 port for software interface/ SNMP enabled
Optional SNMP interface/ Web enabled RMIC interface

Connection

Cold Start Facility Available


Product Range